What the advisory says
CVE-2026-116600 is a memory leak involving WebSocket use with the OWB module in Apache Tomcat. Apache says memory was not released after its effective lifetime, which could lead to denial of service. The Tomcat 11 advisory lists versions 11.0.0-M1 through 11.0.27 as affected and marks the issue Important.
The OWB integration condition matters. A Tomcat deployment that does not use WebSocket with OWB may not reach this path. Services with long-lived or frequent WebSocket connections should identify the integration and review memory behaviour over time.
Checks for your systems
Inventory Tomcat applications that enable WebSocket and identify whether they integrate OWB. Check dependency manifests and deployment configuration. Review memory trends, connection lifetimes and restart events, then compare them with normal workload patterns.
Apache lists a fix in Tomcat 11.0.29. Check the security pages for the corresponding release in other Tomcat branches. Upgrade and validate WebSocket connection handling, OWB-dependent features and memory use under a representative workload.